11-28
CONTROL SYSTEM
Revision Y06-02 Service Manual - KN Series
b. High Pressure Protection (excluding RH Group)
Mode: (AUTO) HEATING
Fan: Any
Timer: Any
I-FEEL: ON or OFF
Control Function
Protects the compressor from high pressure by switching OFF the OFAN and COMP
.
ICT [
o
c]
Any
Off
Any
Off
COMP
OFAN
52
55
61
66
COMP is forced OFF
67
OFAN is force
Off
COMP is forced OFF
For all models except WAX For WAX model
ON
BLINK
OPER
LED
CONTENT