RESTART AFTER A LONG TIME
1. Check before operation
Check that air outlets of the outdoor and indoor are not blocked.
Check that the ground wiring is not broken off and is connected well.
2. Restore the air filter and the front panel
The air filter and the front panel must be fixed to the original position after having been cleaned.
3. Connect the main power switch
To protect the air conditioner, power should be provided 12 hours before operation. Then the
OPERATION lamp on the control box of the indoor unit will flash once a second .
PHENOMENA NOT CONCERNING MALFUNCTIONS
1. No operation
The air conditioner does not work immediately after button is pushed.
For each Mode including Power OFF and SB, a Min time delay of 3 min before Comp. restarting,
excluding Deicing Mode.
2. A white mist of chilled air is generated from the indoor unit.
Cooling in a room with a high relative humidity (in a place with much oil mist or dusts),
The room temperature will be uneven if there is much filth inside the indoor unit. In this case, cleaning
is necessary. This work requires qualified person.
If the air conditioner heats right after defrosting, the water will be sent out in the form of steam.
3. Noise
A kind of continuous low sound of hiss could be heard while the air conditioner is on operation. This is
caused by Freon flowing between the indoor and outdoor units causes this.
A kind of hiss could be heard during the time of defrosting or right after stop. This is caused by Freon
changing its flow volume or not flowing any more.
A kind of continuous low sound of rustle could be heard while the air conditioner is on
COOLING(including AUTO)or DRYING. This is caused by the drain pump which is running .
A kind of squeak will be heard while the air conditioner is on or off operation. This is caused by the
inflation or deflation of the plastics of the unit due to the temperature fluctuation.
4. Dusts are blown out of the indoor unit
This occurs only in the case of the first use after a longtime rest.
5. Bad odor is coming out from the indoor unit
This is because the indoor unit gives off the smell impregnated from the wall, furniture, or smoking.
6. Turning to FAN ONLY while COOLING
To prevent the heat exchanger from frosting, turn to FAN ONLY mode automatically and the
COOLING mode will be restored before long.
When the room temperature reaches the set one, the compressor will stop to turn to FAN ONLY. In
the HEATING mode, the process is reversed.