The labelling classifies
air conditioning systems
in 7 categories
(from A to G) in relation
to their energy
consumption. Those
appliances with the
best energy efficiency
are awarded an A label
(Green colour arrow on
the label) those with the
lowest energy efficiency
a G label (Red colour
arrow). This label also
includes a certain number
of details (Brand, Model,
Cooling and heating
capacity, Noise level)
and allows the user
to compare the efficiency
of different products.
Indication of annual energy consumption
Based on a standard model, this annual consumption
is calculated by multiplying the total capacity by an
average running time of 500 hours per annum in Cooling
mode and under full load.
• Cooling capacity
The refrigerating capacity is defined as the cooling
capacity in kW of an appliance, running in Cooling mode
under full load.
EER or Energy Efficiency Ratio
This is the ratio between the refrigerating capacity
and the amount of electricity consumed to attain it.
In other words, the higher the EER, the better the energy
efficiency.
Energy Efficiency Categories* in cooling mode
A EER > 3.2 E 2.6 > EER > 2.4
B 3.2 > EER > 3.0 F 2.4 > EER > 2.2
C 3.0 > EER > 2.8 G 2.2 > EER
D 2.8 > EER > 2.6
• Heating Capacity
Heating capacity is defined as the Heating capacity in
kW of an appliance running in Heating mode and under
full load.
COP or Coefficient of Performance
This is the ratio between the Heating capacity and the
quantity of electricity consumed to attain it. In other
words, the higher the COP, the better the energy
efficiency.
Energy Efficiency Categories* in heating mode
A COP > 3.6 E 2.8 > COP > 2.6
B 3.6 > COP > 3.4 F 2.6 > COP > 2.4
C 3.4 > COP > 3.2 G 2.4 > COP
D 3.2 > COP > 2.8
* only for splits and multisplits.
295
2.2
3.3
2.5
A
30
UE 7 DCI
UI Delta 7 DCI
A
7
ELECTRA 2008 AIR CONDITIONING & HEATING CATALOGUE
Energy
Manufacturer
Outside unit
Inside unit
More efficient
Less efficient
Annual energy consumption,
kWh in cooling mode
(Actual consumption will depend
on how the appliance is used
and climate)
Cooling output kW
Energy efficiency ratio
Ful load (the higher the better)
Type
Cooling only
Cooling + Heating
Air-conditioner
Air cooled
Water cooled
Heat output kW
Heating performance
A: higher G: lower
Noise
(dB(A) re 1 pW)
Further information is contained
in product brochures
Norm EN 814
Air-conditioner
Energy Label Directive 2002/31/EC
A
B
C
D
E
F
G